Figure 3-8 Clearance Required for Tabletop or Shelf Installation
A = 15 cm (6 in)
B = 57 cm (22.5 in)
C = 53 cm (21 in)
D = 213 cm (7 ft)
3.7.1

Rackmount Installation

To install the device in a 19-inch rack, you need the following items shipped with the device.
A strain-relief bracket, four M4 x 6 mm pan-head screws, and tie wraps
Two rackmount brackets and mounting screws
Also needed are four user-supplied screws to attach the device to a standard 19-inch rack.
3.7.1.1

Guidelines for Rackmount Installation

The installation site must be within reach of the network cabling and meet the requirements listed
below:
Appropriate grounded power receptacles must be located within seven feet of the location.
A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation
site with fluctuations of less than 10°C (18°F) per hour.
CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the device.
WARNING: Before installing the device into a rack, ensure that the rack can support the
device(s) without compromising the stability of the rack. Otherwise, personal injury
and/or equipment damage may result.