Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Broil Burner Igniter Removal

Condition Requirements:
Door Assembly Removed
1. Remove screws and pull igniter wire into oven cavity.
2. Disconnect wire to remove igniter from range.
(View of top of oven cavity)
3. Reverse procedure for installation.

Temperature Sensor (RTD) Removal

Condition Requirements:
Door Assembly Removed
1. Remove screws that attach the sensor to the back of
the oven liner.
2. Pull the sensor until the connector is in the oven
cavity.
3. Disconnect the connector.
Note: When installing the oven sensor, it may be
helpful to insert a small screwdriver or awl into
the connector and push the wiring and connector
into place.
4. Reverse procedure for installation.
24

Convection Fan Assembly Removal

Condition Requirements:
Rack Supports Removed
1. Lift to remove oven cavity bottom panel from range.
2. Remove five screws and fan cover from oven cavity.
3. Remove four outer screws and convection motor
assembly from oven cavity.
4. Mark and disconnect two connectors from convection
motor assembly.
5. Remove left hand nut and fan blade from convection
fan.
6. Reverse procedure for installation.