Troubleshooting
Component Characteristics
Component
Oven Control
Thermostat
Direct Spark Module -
Bake selected
Direct Spark Module -
Broil selected
Bake Solenoid
Broil Solenoid
RTD (Resistive
Thermal Device)
Convection Motor
**High Limit -
open contacts
**High Limit -
closed contacts
Cycle Light
Oven Light Switch -
OFF
Oven Light Switch -
ON
Single Point Spark
Module
*Resistance checks made with power off.
** High limit switch is N.C. (normally closed) and opens at 275°F.
18
Component Testing
Operating Voltage
(Approximate)
750
120 VAC
120 VAC
Not Applicable
120 VAC
Not Applicable
210
10.5 VAC
210
10.5 VAC
1090 at 75°F
0 VAC
39.4
120 VAC
120 VAC
∞ (Open)
0
0 VAC
120 VAC
Open (neon light)
120 VAC
∞ (Open)
0
0 VAC
120 VAC
Not Applicable
*Resistance
(Approximate)
L1 black - N white
H1 violet - N white
H2 blue - N white
S1 brown - SC black/white
S2 yellow - SC black/white
P4 yellow - yellow
Convection switch (open)
red/white - White
Power cord black - disconnect black
Power cord black - disconnect black
Cycle light terminals - black to white
Oven light switch terminals - black to red
Oven light switch terminals - black to red
Single Point Spark Module - black to white
Test Location
©2010 Viking Preferred Service