Advanced Entry Calibration (continued)
Step
Action
Use the buttons to set the
Gain Number determined
L
in the previous step. Press
ENTER to enable the
setting.
Complete a table (see
example below) using new
measurements, as
follows:
(A) Raise the Printhead
Assembly. Place the
label over the Media
Sensor then lower and
latch the Printhead
Assembly. Record the
sensor reading as P.
(B) Raise the Printhead
Assembly. Place the
M
liner, notch, or mark
over the Media Sensor
then lower and latch
the Printhead
Assembly. Record the
sensor reading as G
(or M).
(C) Raise the Printhead
Assembly. Remove all
media from the Media
Sensor then lower and
latch the Printhead
Assembly. Record the
sensor reading as E.
Gain Number
18
H-Class
Displayed Message
TRAN SENSOR GAIN
yyy
(0 - 31)
TRAN SENSOR GAIN
yyy
(0 - 31)
Selected Gain Table
Paper
Gap (or Mark)
173
42
Comment
This example uses Gain
Number 18.
18
Where 'yyy' is a
numerical value
representing the current
sensor reading.
The re-sampled
values may differ
18
from those
previously noted.
This is normal; do
not readjust the
Media Sensor.
Empty
9
85