Datamax H-4212X Operator's Manual page 58

H class series
Hide thumbs Also See for H-4212X:
Table of Contents

Advertisement

Printer Options (continued)
Menu Item
GPIO PORT
GPIO DEVICE
DISABLED
APPLICATOR
APPLICATOR 2
BARCODE VERIFIER
START OF PRINT
LOW PULSE
HIGH PULSE
ACTIVE LOW
ACTIVE HIGH
EDGE
48
Controls the optional Applicator Interface Card's GPIO
function, where:
Sets the option to work with a specific device type,
where:
Disables the option.
Enables the following GPIO parameters for label
applicator functions:
De-asserts Data Ready (DRDY) when the last label
starts printing to indicate completion;
FEED allowed at any time; and,
Does not de-assert DRDY upon PAUSE.
Enables the following GPIO parameters for label
applicator functions:
Data Ready (DRDY) overlaps End of Print (EOP)
signal by about 1 msec. to indicate completion;
DRDY signal end inhibits FEED; and,
De-asserts DRDY upon PAUSE or FAULT.
Enables the GPIO Port to work with a bar code verifier.
Selects the type of input signal required to initiate
Start of Print (SOP), where:
Triggers printing with a low pulse.
Triggers printing with a high pulse.
Triggers printing with a low signal.
Triggers printing with a high signal.
Triggers printing with a signal edge transition.
Details
H-Class

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents