Datamax H-4212X Operator's Manual page 92

H class series
Hide thumbs Also See for H-4212X:
Table of Contents

Advertisement

Advanced Entry Calibration (continued)
Step
Action
Use the buttons to set the
Gain Number to 00 and
then press ENTER.
Record the sensor reading
F
as a Label Value for Gain
Number 00 in a table (32
rows by four columns,
with headings similar to
those shown below.)
Gain Number
00
01
02
...
31
Step
Action
Use the buttons to
increment the Gain
Number by one and then
G
press ENTER. Record the
Label Value. Repeat this
process for each Gain
Number.
Gain Number
00
01
02
...
31
82
Displayed Message
TRAN SENSOR GAIN
yyy
Sample Calibration Table
Label Value
TOF Value
252
Displayed Message
TRAN SENSOR GAIN
yyy
Sample Calibration Table
Label Value
TOF Value
252
250
248
...
09
Comment
This is the Label Value for
a gain setting of 00,
where 'yyy' represents
(0 - 31)
the current sensor
00
reading.
Difference Value
Comment
These are Label Values,
where 'yyy' represents
(0 - 31)
the current sensor
01
reading.
Difference Value