5.2 Calibration

Calibration ensures correct media detection. Use Standard Calibration if the quick method
(see Section 3.4) fails.
5.2.1

Standard Calibration

Standard Calibration provides dynamic readings, which can be helpful when using media
with small position-critical notches or marks. Three calibration samples are required:
Empty – with nothing over the sensor;
Gap (or Mark) – with media liner, a notch, or a mark over the sensor; and,
Paper – with the label (and liner, if any) over the sensor.
Calibrate the Media Sensor using the steps below:
Before proceeding, ensure that the ADVANCED MENU is enabled (see Section 4.2.4)
and that the SENSOR TYPE is selected (see Section 4.2.1).
Step
Action
A
Turn ON the printer.
Press ENTER to access
MEDIA SETTINGS. Then
B
using the UP Button, scroll
to SENSOR CALIBRATION.
Press ENTER to access
SENSOR CALIBRATION.
Press ENTER again to
C
select PERFORM
CALIBRATION and then
press YES to proceed.
With no media installed,
D
press ESC.
78
Displayed Message
CANNOT CALIBRATE
-or-
UNCALIBRATED
MEDIA SETTINGS
PERFORM CALIBRATION
REMOVE LABEL STOCK
PRESS ESC KEY
yyy
Comment
Wait briefly for the
printer to initialize.
ADVANCED MENU must
be enabled to access the
calibration selections.
Press NO to abort this
procedure.
This sets the empty
value, where 'yyy'
represents the current
sensor reading.