Requirement
a CombiDoctor field
b Setting window
c Roller
➢ Water connection is opened
➢ Energy optimization system deactivated (optional)
➢ Cooking zone empty, no grates and no containers, with support rack or
tray trolley
➢ The unit is on
➢ No errors displayed
➢ Equipment functions displayed
Settings
a) Open the
menu.
b) Enter the password.
c) Tap the "CombiDoctor" field.
d) Using a wiping gesture, set the roller to the desired self-diagnostic
program.
⇨ The set self-diagnostic program displays the elapsed time.
e) Press the "START" button.
⇨ A help text is displayed.
f) Open the cooking zone door briefly and then close it.
⇨ The self-diagnostic program continues automatically.
⇨ On completion of self-diagnosis, the result is displayed. Note the error
message and forwarded to your local customer service.
Cleaning and caring for the unit
Inspecting the unit
d Remaining time
e START button