Description of Functions and Constants
Note
FWD RUN command
REV RUN command
Output frequency
Note
FWD RUN command
REV RUN command
Output frequency

2-8-21 Other Functions

Item name
Function setting
Operation Continued
at Momentary Stop
S-curve characteristics time refers to the time from acceleration
rate 0 to the time when a normal acceleration rate determined by a
specified acceleration time is obtained.
Time chart at FWD/REV run change with S-curve characteris-
tics:
The figure below shows the time chart at FWD/REV run change
during deceleration and stop.
Acceleration
Min. output frequency
No-07
: S-curve characteristic
When digits 3 and 4 are 00, no S-curve characteristics at comple-
tion of deceleration.
Time chart at FWD/REV run change without S-curve charac-
teristics:
The figure below shows the time chart at FWD/REV run change
during deceleration and stop.
Acceleration
Min. output frequency
No-07
No. 46
Digit 1 = 0: When momentary stop is detected, power failure (UV
fault) occurs and the Inverter output is shut off.
Digit 1 = 1: If momentary stop time is within momentary assurance
time (see note), the operation continues after the momentary stop.
If the momentary assurance time is exceeded, the Inverter output
is shut off.
Deceleration
Min. output
frequency
No-07
Acceleration
Deceleration
Min. output
frequency
No-07
Acceleration
Constant to be set
Section 2-8
DC injection braking
time stopping
No-27
Deceleration
DC injection braking
time at stopping
No-27
Deceleration
Factory preset
0110
59