Operation Using Control Circuit Terminal Inputs
Operation Procedure
1, 2, 3...
1, 2, 3...
Check Points
3. Set the frequency value using the Up and Down Arrow Keys or
the RESET Key.
4. Press the DATA/ENTER Key to enter the frequency value.
5. Press the RUN Key.
6. To stop, press the STOP Key.
In this Mode, the Inverter is operated by a frequency setter and/or
operation switches connected to the control circuit terminal. To
operate Inverters with Digital Operators in this Mode, the value of
constant no. 01 must be reset to 0000.
Inverter
Power
supply
3G3XV
Fwd signal
Rev signal
Ferq. setter
Follow the procedure below to set constant no. 01 to 0000 and
enable operation using the control circuit terminal inputs.
1. Turn the power on.
2. Press the PRGM/DRIVE Key to enter Program Mode.
3. Set constant no. 01 to 0000 using the Up and Down Arrow Keys
or the RESET Key.
4. Press the DATA/ENTER Key to enter the new value. for con-
stant no.01.
5. Press the PRGM/DRIVE Key to enter Drive Mode.
Follow the procedure below to operate the Inverter using control
circuit terminal inputs.
1. Turn the knob on the frequency setter all the way to the left to
set the frequency reference=0.
2. Turn ON the FWD or REV run signal.
3. Turn the frequency setter knob slowly to the right to increase
the frequency setting to its full value.
4. To stop, turn the frequency setter knob slowly to the left to
decrease the frequency setting to zero and then turn OFF the
FWD or REV run signal.
Motor rotation is smooth.
Motor rotating direction is proper.
Motor does not have abnormal vibration or beat.
Accel/decel is smooth.