Troubleshooting The Administration Terminal - Northern Telecom Meridian 1 Installation And Maintenance Manual

Hide thumbs Also See for Meridian 1:
Table of Contents

Advertisement

Page 176 of 220 Troubleshooting
Table 40 : Card LED behavior (continued)
Connected to
CMCC?
already
disabled
connected
already
disabled
connected
already
reenabled from either side after being
connected
disabled from both sides

Troubleshooting the Administration Terminal

553-3601-200 Standard 7.00 November 1998
Meridian 1:
enabled/
disabled
enabled/disabled
system enabled;
individual cards
disabled
disabled
Note: If the CMCC system LED has stopped flashing and the Administration
Terminal has no display, it is not properly connected to the CMCC. If
the CMCC system LED stops flashing but the Administration Terminal
button LCDs continue to flash, the Administration terminal is not
connected to one of the first five TCM ports on the CMCC. In either
case, check the main distribution frame wiring and correct any problem.
1.
Check that the time and date appear on the display.
2.
Check the display. If the display is unreadable, ensure that the display
contrast adjustment (ƒ•‡) is adequate.
3.
Check that power is on in the system.
4.
Check that the Administration Terminal is connected to the correct port.
5.
Check the 50-pin connectors at the system and make sure they are
plugged in properly.
6.
Check the 25-pair TCM cables at the distribution frame to make sure
they are connected to the right ports.
7.
Check the telephone wiring connections at the distribution frame to
make sure the connections have been made on the appropriate
connectors (see "Installing the hardware" chapter).
Meridian
Companion
Companion:
system power
powering up
normal
normal
LED behavior
status
flash three times,
go on, then LEDs
of disabled cards
stay on; others go
off slowly
LED goes on
LED goes off