12 Specific data IO-Link (pin 6)
12.4.3 Device Access Locks
Access to the parameters can be controlled with the Device Access Locks parameter.
Index
Sub-
Off-
Index
set
0x0C
1
0
2
1
3
2
4
3
Description of parameter values
Parameter
Parameter (write)
access
Data Storage
Local parameteriza-
tion
Local user interface
12.4.4 Vendor Name
The manufacturer name can be read out in ASCII format with the Vendor Name parameter.
Index
Sub-
Off-
Index
set
0x10
0
12.4.5 Product Name
The device name can be read out in ASCII format with the Product Name parameter.
Index
Sub-
Off-
Index
set
0x12
0
12.4.6 Serial Number
The serial number of the device can be read out with the Serial Number parameter.
The serial number consists of an 8-digit completion confirmation number, a forward slash and a 4-digit index.
Index
Sub-
Off-
Index
set
0x15
0
GEMÜ 533
Positioner (Code S0)
Access
Length
Rights
R/W
1 bit
Parameter (write) ac-
R/W
1 bit
R/W
1 bit
Local parameterization
R/W
1 bit
Local user interface
Values
0
Enable write access
1
Block write access
0
Enable storage of parameter data in the IO-Link master
1
Block storage of parameter data in the IO-Link master
0
Enable local parameterization
1
Block local parameterization
0
Enable local user interface
1
Block local user interface
Access
Length
Rights
RO
5 bytes
Access
Length
Rights
RO
14 bytes
Access
Length
Rights
RO
13 bytes
Parameter
Type
BooleanT
cess
Data Storage
BooleanT
BooleanT
BooleanT
Description
Parameter
Type
Vendor Name
StringT
Parameter
Type
Product Name
StringT
Parameter
Type
Serial Number
StringT
28 / 52
Values
0
1
0
1
0
1
0
1
Values
"GEMUE"
Values
"eSyStep Positioner"
Values
"XXXXXXXX/YYYY"