Troubleshooting - Yellow Error Light - GBC DELTA Operator's Manual

Table of Contents

Advertisement

Delta Laminator
3.2
TROUBLESHOOTING – YELLOW ERROR LIGHT
The machine error is signaled by yellow indicator ERROR (lit up continuously or blinking) and the
error/status message on the operator's panel in the right at the top. By touching this part of the panel,
you get to the Error Screen where the error/status is described in detail.
3.2.1
Error
incorrect sequence of phases
Status indication:
Operator's panel, Main screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Switch the machine off.
Change the sequence of the phases on the machine supply unit.
Switch the machine on.
3.2.2
Status – the safety relay is not active
Status indication:
START button/indicator is blinking with short flashes
Yellow ERROR indicator is blinking with short flashes
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Check the switching position of both emergency stop buttons.
Close all the machine covers.
Switch on the safety relay by pressing buttons START.
If the safety relay cannot be switched on by pressing button START even after the previous
steps, there must be an error the electrical connection (for example a loose conductor). See
wiring diagram DA-41-100n, Sheet 4.
© 2004 General Binding Corporation
Bad phase sequence
of power supply
Safety relay is not active
Check emergency stop
Close covers
Press button START
Service Manual – Electrical
ERROR
Phase sequence
STATUS
Safety relay
21