Service Manual – Electrical
Status correction:
First it is necessary to establish if the error is in the pulse generation or on the main drive. You
can check it as follows:
-
Press the "START" button/indicator again to quit the error, if the error persists, it will appear
again.
-
If the laminating roll turned by approximately 1 in. (1 cm), the error is on the pulse
generation.
-
If the laminating roll did not turn at all, there is an error in the main drive function.
Correction of the error in the pulse generation:
-
The error is possibly caused by disconnection of conductors 601, 602 (phase A, phase B of
the IRC encoder) or 217, 215 (24 Vdc, 0V supply to the IRC encoder). Repair. See DA-41-
100n, sheet 6.
-
Defective IRC encoder. Replace it.
-
Defective rapid inputs X0, X1 on PLC of the machine control system. Replace.
Correction of the errors in the main drive function:
-
The error may be caused by disconnection of conductor 906, which controls frequency
inverter U1. Repair it. See DA-41-100n, sheet 9
-
Frequency inverter U1 failed. Reset the error by the control unit or by switching the machine
off and on. More detail about the frequency inverter - see the Mitsubishi manual.
-
Frequency inverter U1 is defective. Replace it.
-
Motor M1 is defective. Replace it.
-
The error may be caused by disconnection of conductors 309, 310, 311 – interconnection
between frequency inverter U1 and motor M1. Repair. See DA-41-100n, sheet 3.
-
The error may be caused by disconnection of conductors 307, 308, N – power supply to the
frequency inverter. Repair. See DA-41-100n, sheet 3.
3.2.9
Error – the loading table is in the upper limit position
Status indication:
Yellow ERROR indicator is lit up continuously.
Operator's panel, Main Screen, 1st status line:
Operator's panel, Main Screen, 2nd status line:
Error Screen:
Status correction:
Move the loading table down and quit the error by pressing the "FEEDER DOWN" button and
simultaneously move the loading table off the top limit switch.
24
Feeder is in upper position
Press button Feeder DOWN
ERROR
Feeder top
© 2004 General Binding Corporation