GBC DELTA Operator's Manual page 26

Table of Contents

Advertisement

Delta Laminator
4.2.4 Main Screen – Description
Hidden button (area)
for transfer into Error
Screen
Display of actual
temperature - middle
of laminating roll
Bar-graph of actual
temperature
Display of desired
temperature
Bar-graph of desired
temperature
Area for recall of
numeric keyboard for
input of desired
temperatures
Procedure for setting the desired temperature:
1. Touch at the desired temperature in the area of the bar-graph to call the numeric button
panel.
2. Enter the number of the desired temperature by pressing the buttons and confirm by
pressing Enter. (Heating gets activated when the "HEATERS" switches are set to the
"START" position).
© 2004 General Binding Corporation
Operator Manual
Machine status - 1st
line (STATUS /
ERROR)
Machine status - 2nd
line, short
information on
machine errors
Display of number of
sheets
Button for transfer to
Screen No. 2
Display of machine
speed in m/min
Tachometer
27