Delta Laminator
Service Manual – Mechanical
2.10 GATE II
2.10.1 Gate II Control Mechanism
Gate II is controlled from the pneumatic cylinder (b), which turns the lever (c) and therefore the whole
bar with the gate (a).
b
c
a
2.10.2 GATE II POSITION
The upper edge of the gate II must exceed the guide plate by 3/32 to 7/64 in. (2.3 to 2.7 mm). The
position is set by the manufacturer and can be adjusted only by a GBC Service technician.
a