3 | Safety and compliance

3.1 | Safe handling

An unpopulated enclosure can weigh up to 46kg (101lb). Use appropriate lifting methods.
A fully populated enclosure weighs 135kg (298lb). You must lift the enclosure when the
drawers are empty and latched closed. Do not attempt to lift the enclosure when populated
with drives.
When closing the drawers, do so firmly, ensuring the latches are engaged.
Please use belt straps to lift the enclosure out of the box.
Do not try to lift the enclosure by yourself.
Use appropriate lifting methods. Before lifting the enclosure:
Remove DDICs drive carriers from drawers and verify the drawers are closed and firmly
o
locked.
Use a minimum of three people to lift the enclosure using the lifting straps provided.
o
Avoid lifting the enclosure using the handles on any of the CRUs because they are not
o
designed to take the weight. Lift from underneath the main enclosure.
Observe the lifting hazard label affixed to the storage enclosure.

3.2 | Safety

This equipment is for installation in a Restricted Access Location only.
A restricted access location is where:
Access can only be gained by service persons or users who have been fully instructed on
o
the reasons for the restrictions applied to the location and on any precautions that must
be taken.
Access is through the use of a tool or lock and key, or other means of security, and is
o
controlled by the authority responsible for the location.
Caution
If this equipment is used in a manner not specified by the manufacturer, the
manufacturer warranty provided by the equipment may be impaired.
All drives and rear modules are part of the 5U84 storage enclosure and must only be removed
when a replacement can be immediately added. The system must not be run without all rear
modules in place.
Permanently unplug the enclosure before you move it or if you think that it has become
damaged in any way.
Always remove the drives, Power Supply Units (PSUs), controllers, and System fans to
minimize weight before you move the enclosure.
A safe electrical ground connection must be provided to the power supply cords.
Important
The enclosure MUST be grounded before applying power.