Fabric OS command line interface

Although many different software and hardware configurations are tested and supported by
Brocade Communications Systems, Inc., documenting all possible configurations and scenarios is
beyond the scope of this document. In some cases, earlier releases are highlighted to present
considerations for interoperating with them.
The hardware reference manuals for Brocade products describe how to power up devices and set
their IP addresses. After the IP address is set, you can use the CLI procedures contained in this
guide. For additional information about the commands used in the procedures, see online help or
the Fabric OS Command Reference.

Fabric OS command line interface

Fabric OS uses Role-Based Access Control (RBAC) to control access to all Fabric OS operations.
Each feature is associated with an RBAC role and you will need to know which role is allowed to run
a command, make modifications to the switch, or view the output of the command. To determine
which RBAC role you need to run a command, review the section
(RBAC)"
NOTE
When command examples in this guide show user input enclosed in quotation marks, the quotation
marks are required.

Console sessions using the serial port

Note the following behaviors for serial connections:
Connecting to Fabric OS through the serial port
1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on
2. Open a terminal emulator application (such as HyperTerminal on a PC, TERM, TIP, or Kermit in
16
on page 84.
Some procedures require that you connect through the serial port; for example, setting the IP
address or setting the boot PROM password.
Brocade 48000 director and Brocade DCX and DCX-4S enterprise-class platforms: You can
connect to CP0 or CP1 using either of the two serial ports.
the workstation.
If the serial port on the workstation is RJ-45 instead of RS-232, remove the adapter on the end
of the serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on
the workstation.
a UNIX environment), and configure the application as follows:
In a Windows environment enter the following parameters:
Parameter
Bits per second
Databits
Parity
Stop bits
Flow control
Value
9600
8
None
1
None