Table 1 Daemons That Are Automatically Restarted - Brocade Communications Systems 53-1001763-02 Administrator's Manual

Brocade communications systems iron user manual
Table of Contents

Advertisement

Schedule downtime and reboot the switch at your convenience.
considered non-critical and are automatically restarted on failure.
TABLE 1
Daemon
arrd
cald
raslogd
rpcd
snmpd
traced
trafd
webd
weblinkerd
Fabric OS Administrator's Guide
53-1001763-02
Daemons that are automatically restarted
Description
Asynchronous Response Router, which is used to send management data to hosts when the switch
is accessed through the APIs (FA API or SMI-S).
Common Access Layer daemon, which is used by manageability applications.
Reliability, Availability, and Supportability daemon logs error detection, reporting, handling, and
presentation of data into a format readable by you and management tools.
Remote Procedure Call daemon, used by the API (Fabric Access API and SMI-S).
Simple Network Management Protocol daemon.
Trace daemon provides trace entry date/time translation to Trace Device at startup and when
date/time changed by command. Maintains the trace dump trigger parameters in a Trace Device.
Performs the trace Background Dump, trace automatic FTP, and FTP "aliveness check" if auto-FTP
is enabled.
Traffic daemon implements Bottleneck detection.
Webserver daemon used for WebTools (includes httpd as well).
Weblinker daemon provides an HTTP interface to manageability applications for switch
management and fabric discovery.
High availability of daemon processes