Furuno FCV-38 Manual page 66

Hide thumbs Also See for FCV-38:
Table of Contents

Advertisement

2. GRAPH FUNCTIONS
[Auto Specific Area]
[Updating Cycle]
[Measurement Range]
[Measurement Threshold]
4. Click the [OK] button to finish, or click the [Cancel] button to quit and restore pre-
vious setting(s).
SIZE1 - SIZE3 menus
The following menu items change according the measurement mode.
• [Specific Area] measurement mode: Since the [SIZE2] and [SIZE3] menus are en-
abled, the fish length graph can be set individually. For example, the [SIZE2] fish
length graph is set in the [SIZE2] menu.
• Measurement mode other than [Specific Area]: The menu settings for the [SIZE1]
menu are reflected to the fish graph.
1. Click the [Advanced Settings] icon (
the [Advanced Settings] icon (
2. Click [SIZE1], [SIZE2] or [SIZE3].
FCV-38[0252473-xx.xx]
2-8
Item
[Auto Measurement Range Time Direction]: Available
when [Auto Specific Area] is set to other than [Off]. Set
the area to use in automatic area adjustment.
• [Entire Area]: Automatic adjustment on all areas.
• [1/2]: Automatic adjustment is done from the right
• [1/3]: Automatic adjustment is done from the right
Sets the updating interval for the fish graph.
Sets the depth range for fish size measurement for all
modes except bottom trace.
[Std]: Measurement from the transducer to the seabed.
[Entire Range]: Include fish echoes beyond the seabed.
This option is useful in situations where the seabed is not
detected correctly, as it can detect fish which are below
the incorrectly detected seabed.
Sets the minimum fish size (setting range: 5 - 20 cm) at
which to begin fish size detection.
Description
edge of the screen to 1/2 the screen width.
edge of the screen to 1/3 the screen width.
) from the InstantAccess bar™, then click
) to show the [Advanced Settings] window.

Advertisement

Table of Contents
loading

Table of Contents