Tests Menu - Furuno FCV-38 Manual

Hide thumbs Also See for FCV-38:
Table of Contents

Advertisement

6. MAINTENANCE AND TROUBLESHOOTING
Error
Error name
Icon
Processor Unit
System Error
Transceiver Unit
System Error
6.7

Tests Menu

You can run a diagnostic test, or view detailed information about your equipment, from
the [Tests] menu.
To access the [Tests] menu, do the following:
1. Click the [Advanced Settings] icon (
the [Advanced Settings] icon (
2. Click [Tests] to show the [Tests] menu, on the right-hand side of the window.
FCV-38[ver 0252473-xx.xx]
6-6
Error
code
P01
The voltage of the battery inside the Proces-
sor Unit is low. Turn the equipment off, then
contact your local dealer to request replace-
ment of the battery.
P02
The fan is in the Processor Unit is rotating too
slowly. Turn the equipment off, then contact
your local dealer to request replacement of
the fan.
P05
Multiple alike IP addresses found. Turn the
equipment off, then contact your local dealer
for advice. (IP address setup is in the [Ser-
vice] menu.)
T01
Communication error between the Trans-
ceiver Unit and Processor Unit. Turn the
equipment off, then contact your local dealer
for service.
T03
The rotating speed of the FAN1 in the Trans-
ceiver Unit is abnormal. Turn the equipment
off, then contact your local dealer for service.
T04
The rotating speed of the FAN2 in the Trans-
ceiver Unit is abnormal. Turn the equipment
off, then contact your local dealer for service.
) to show the [Advanced Settings] window.
* These items are for maintenance/service
purposes and are not accessed normally.
Reason, remedy
) from the InstantAccess bar™, then click
Priority
Order
4
5
6
3
7
8
*
*
*

Advertisement

Table of Contents
loading

Table of Contents