5.4.3

Operations available after completion of the measurement

The following operations are available after the completion of the measurement.
• Edit the calibration results.
• Extract measured area using the directivity display (1D).
How to edit calibration results
Follow the procedure below to edit calibration results.
1. Click the (
show the [Calibration File Select] window.
If no external memory device is connected, go to step 3. Otherwise, go to step 2.
2. From the drop down list below the title bar, select the location ([Internal Memory]
or [External Memory]) of the calibration file.
A list of files stored in the selected memory appears.
The left side of the above figure appears only when an external recording device
is connected.
3. Select the calibration file to use.
Note 1: You can copy calibration files to the internal memory and external mem-
ory. To copy a file, select the file, then click the Copy button (
left corner of the window.
Note 2: To delete a calibration file, select the file, then click the Delete button (
at the bottom-left corner of the window. The message "The selected file will be de-
leted. Are you sure?" appears. Click the [OK] button to delete the file.
4. Click the [OK] button. The file selected at step 3 in loaded, and reflected to the
[Calibration Setting] window. If file error is found, the message "Cannot read the
file correctly.Check the file and contents." appears.
5. Change the values of [Theoretical TS] and [Calibration Value] manually.
The calibration value is changed with adjustment of the theoretical TS.
6. To apply edited calibration values to this unit, click the [OK] button (or [Apply] but-
ton) the [Calibration Setting] window. The message "Re-calculate the calibration
and theoretical values?" appears.
7. Click the [Yes] button. The message "Calibration values changed. Overwrite cur-
rently saved data?" appears.
) button for [Calibration File] on the [Calibration Setting] window to
File location drop-down list
5. CALIBRATION
5
) at the bottom-
)
5-15