b) Removing from "Q3 □ DB"
R e m o v e th e s c re w , if th e
u n it fix in g s c re w is b e in g
u s e d .
H o ld th e u n it w ith b o th
h a n d s a n d p u s h th e
u p s id e h o o k fo r fix in g ,
u n til it s to p s .
P u s h th e h o o k fo r u n it
fix in g , u s e lo w e r p a rt a s
th e fu lc ru m a n d p u ll it to
th e fro n t.
H o ld in g u p th e u n it, a n d
re m o v e th e p ro je c tio n
s e c tio n fo r fix in g fro m
th e h o le
Complete
<Point>
・Remove the screw, if the unit fixing screw is being used.Next, remove the projection for unit fixing from the
unit fixing hole. If it tries to remove the unit by force, the projection for unit fixing will be damaged.
CAUTION
Since the heat dissipation fin of the robot CPU unit may become the high temperature
for a power supply on, and after power supply off, please do not touch. It becomes the
cause of the burn. When you remove the unit, be careful of the handling.
Push
Hook for unit fixing
Base unit
Unit
connector
Unit fixing hole
Holding up
Pull to the front
Unit
Installation and connection 2-21
2Unpacking to installation