Grounding The Chassis - Avaya Virtual Services Platform 9000 Installation Manual

Hide thumbs Also See for Virtual Services Platform 9000:
Table of Contents

Advertisement

Virtual Services Platform 9012 chassis
3. Remove the two upper screws from the power cable receptacle panel on the rear of the
chassis.
4. Position the power cable bracket notches over the chassis positioning studs and reuse the
two screws you removed to fasten the power cable bracket as shown. Do not attach any
cables until after the bracket installation.

Grounding the chassis

Ground the chassis before you install power supplies or connect power and network cables to the
system.
Before you begin
• Ensure you have a two-hole cable lug that fits over the grounding studs.
• Ensure you have a nut and a locking washer for the grounding stud.
• Ensure you have a 6-AWG green and yellow grounding wire long enough to connect to the
ground point.
• Ensure you have a 1/4 inch (6 mm) socket or nut driver.
Procedure
1. Crimp the two hole lug onto the ground wire.
October 2015
Installing the Avaya VSP 9000
Comments on this document? infodev@avaya.com
82