Kohler KD83V16 Service And Repair Manual page 176

Table of Contents

Advertisement

Repair
Cooling system
2
T-pipe
3
O-ring
4
Pipe
5
Screw (M10)
6
Flange
7
O-ring
8
Test point fitting
9
Water pump HT
Removal
u Remove screws 1, 5.
u Remove piping assemblies 2, 4, 6.
u Remove two screws 16.
u Install guiding rods.
u Remove remaining screws 16.
u Remove water pump HT 9.
u Remove screws 5, 15.
u Remove cooling medium pipe 13 with flange 6.
u Remove pipe 14 with flange 6.
Installation
u Insert o-ring 7 and flange 6 on pipe from oil cooler casing.
u Mount pipe 14 with o-rings 3 on flange 6.
u Mount cooling medium pipeline 13 with o-ring 7 on flange 6.
u Insert guiding rods in water pump 9.
u Insert o-rings 10, 11, 12.
u Insert water pump HT 9.
u Tighten screws 1, 16 according to tightening specifications.
u Remove guiding rods.
u Tighten remaining screws 16 to torque.
u Assemble t-pipe 2, pipe 4 and flange 6 with o-rings 3, 7, 17.
u Position assembly with screws 1, 5 and tighten according to tightening specifications.
u Install test point fitting 8 on water pump.
Information
Vent coolant circuit at the end of installation.
Setting values
/
Tightening specifications
/
176
11
12
13
14
15
16
17
© 2019 by Kohler Co. All rights reserved.
Service and Repair Manual
O-ring
O-ring
Cooling medium pipeline
Pipe
Screw (M12)
Screw (M12)
O-ring
KD83V16 33525088901_1_1 EN_US
2019-02

Advertisement

Table of Contents