C-38
Alarms Parameters
MIB Parameter
(Location in Parenthesis)
*Alarms
710.3.3. 20
(brzAccessMib 20)
*GpsAlarms
710.3.3. 20.1
(*Alarms 1)
*AlarmInTable
710.3.3. 20.1.1
(*GpsAlarms 1)
*AlarmInTableEntry
710.3.3. 20.1.1.1
(*AlarmInTable 1)
*AlarmInIdx
710.3.3. 20.1.1.1.1
(*AlarmInTableEntry 1)
*AlarmInName
710.3.3. 20.1.1.1.2
(*AlarmInTableEntry 2)
*AlarmInStatus
710.3.3. 20.1.1.1.3
(*AlarmInTableEntry 3)
*AlarmOutTable
710.3.3. 20.1.2
(*GpsAlarms 2)
*AlarmOutTableEntry
710.3.3. 20.1.2.1
(*AlarmOutTable 1)
*AlarmOutIdx
710.3.3. 20.1.2.1.1
(*AlarmOutTableEntry 1)
*AlarmOutName
710.3.3. 20.1.2.1.2
(*AlarmOutTableEntry 2)
*AlarmOutDefinition
710.3.3. 20.1.2.1.3
(*AlarmOutTableEntry 3)
*AlarmOutControl
710.3.3. 20.1.2.1.4
(*AlarmOutTableEntry 4)
*AlarmOutStatus
710.3.3. 20.1.2.1.5
(*AlarmOutTableEntry 5)
Manual Revision: 3.0
Description
Alarms parameters
Applicable to GU only. GPS Alarms parameters.
Applicable to GU only. Names and status of Alarms-In. Not
accessible.
Applicable to GU only. An Alarms In table entry. Not
accessible.
Applicable to GU only. Read-only. Alarms In table index
Applicable to GU only. Alarm In name. Alarms 1 to 4 can
receive a name. The other are read-only.
Applicable to GU only. Read-only. The status (off or on) of
Alarm In entry.
Applicable to GU only. Names, definition, control and status of
Alarms-Out. Not accessible.
Applicable to GU only. An Alarms Out table entry. Not
accessible.
Applicable to GU only. Read-only. Alarms Out table index
Applicable to GU only. Alarm Out name. The other are read-
only.
Applicable to GU only. Enter an Alarm-In number to activate
the Alarm-Out when this Alarm-In is ON. Enter A to activate the
Alarm-Out if ANY of the Alarms-In are ON.
NONE (never activate the Alarm Out).
Applicable to GU only. Alarm out control:
off (0) – turn alarm off.
on (1) – turn alarm on.
auto (2)-activate according to status of relevant alarm-in in
accordance with Alarm Out Definition.
Applicable to GU only. Read-only. The status (off or on) of
Alarm Out entry.
BreezeACCESS Version 4.3 System Manual
Values/Range
Integer
1-10
DisplayString
(SIZE(0..31))
Integer
off (0)
on (1)
na (255)
Integer
1-3
DisplayString
(SIZE(0..31))
DisplayString
(SIZE(0..2))
Enter N for
1-10, A, N
Integer
off (0)
on (1)
auto (2)
na (255)
Integer
off (0)
on (1)
na (255)