3.2.1.2
Configuring the PC Station Hardware with the STEP 7 Hardware
Configuration Application
To configure the PC-based controller and DP I/O for the PC Station, follow these
steps:
1. Open the PC Station folder in the project and double-click the Configuration
icon to invoke the STEP 7 Hardware Configuration application.
2. Navigate to your specific controller under SIMATIC PC Station.
3. Drag the controller into the same index it occupies in the Station Configuration
Editor on the target computer.
4. Verify that the name of the controller matches the name of the controller
configured in the Station Configuration Editor.
5. Configure the distributed I/O.
Windows Automation Center, WinAC Slot Version 4.0
Hardware Installation and Operating Manual, Edition 02/2006, A5E00273194-02
Getting Started
49