Di Driver Scope Window - National Instruments NI DIDS-2103 User Manual

Table of Contents

Advertisement

4.1.1 DI Driver Scope Window

DIX_ScopeRefresh
Tip Strip: Refreshes DI scope data
Detail: When DIX_ScopeRefresh is pressed, the graph will refresh with injector current, in Amps, during the
most recent injection command to the associated DI Driver module. If multiple channels within the module
are operating, it is not possible to identify which channel is being displayed. Note that the resolution of
the current display is approximately 10 µsec sampling interval, and is for reference only. A box instrument
oscilloscope and current probe may be necessary for more detailed information. The voltage trace shown
is not recorded within injection commands. Therefore, the voltage trace will be constant with the last value
recorded before the injection command. Also, the current trace is not recorded outside of the injection
command and will be displayed as zero.