Manually Resetting The Controller Network Interface To Dhcp - National Instruments NI DIDS-2103 User Manual

Table of Contents

Advertisement

Controller Network Interface To DHCP
This section assumes that all attempts have failed to establish connection with the DI Driver System user interface,
and the system controller IP address is unknown.
Before resetting the controller network settings to DHCP mode, consider the
following:
1. Reboot the System Controller
Press and release the reset button on the front of the
USER1 and USER FPGA LEDs to start blinking. The typical time to start blinking is about 25 seconds. A
connection cannot be established with the user interface via SCM until both User LEDs are blinking. If both
LEDs are not blinking, refer to the
2. Use
Search for SCM Target...
If the IP address of the controller is discovered via the Search for SCM Target... dialog, but the Download
Files checkbox does not appear in the dialog, then take note of the discovered IP address. The Windows PC
used to interface with the system must have a similar IP address and Subnet mask as the system controller,
but the IP address must be different in the last address number. The Subnet mask should be 255.255.255.0.
Refer to the
Out Of The Box Connection
3. Use SCM Real-Time Target Backup Feature to Discover the IP Address
From the SCM console, select File, then Real-Time Backup and Restore to open the Real-Time System
Backup dialog.
Press the pull-down arrow in the Target field to see a list of targets available on the network. The list will
show the IP addresses of the targets as shown below.
3.2.2.3 Manually Resetting The
Troubleshooting
to Discover the IP Address
section to see how to change the IP address of the Windows PC.
cRIO-9066
controller. Wait about 1 minute for both the
section.