4.16 Active Flex Control Parameters Window

The purpose of the Active Flex Control Parameters window is to show, within a single window, any Flex Control
Parameters that are selected to be written by one of the DI Driver System software functions. Flex Control
Parameters may be selected within the various setup windows, but the function may be optionally enabled or
disabled. The green LED for each parameter indicates whether the parameter is actively being written by the
function. For example, the screen shot in Figure 4.15.a shows that the 1D-Table 1 output, which is configured via the
Table Setup
window, is actively writing to the PFI_Duration_Chan1_EPT Flex Control Parameter because the table is
enabled. The SimulatedSpeed Flex Control Parameter is also selected to be written by the 1D-Table 2 function, but
the table is not enabled, and is not actively writing the parameter.
Figure 4.16.a, Active Flex Control Parameters