CTP1000 Series Hardware Guide
CTP1004 Platform Specifications and Certification
Table 2: CTP1004 Platform Specifications
Category
Weight
Chassis only
Dimensions
Chassis only
Environmental Requirements
Ambient operating temperature
Ambient operating humidity
DC Input
Voltage
Current
Power
Redundancy (input power)
AC Input
Power required
AC line frequency
Nominal current (115V amps)
Power
Space Requirements
Airflow
14
Specification
12 lb (5.44 kg)
1.75 in. (4.44 cm) high
17.25 in. (43.81 cm) wide
13.9 in. (35.30 cm) deep
32° to 104° F (0° to 40° C)
5% to 90% (noncondensing)
–40 to –72 VDC
1 A @ –48 VDC
48 W
2 independent line feeds
100–132 VAC
200–240 VAC
50–60 Hz
1.5
150 W
3 feet (90 cm) behind device or rack.
Do not block air vents on the front or back of the router.
Air intake occurs from the front of the device.
Air is exhausted out the back side of the device.
Copyright © 2015, Juniper Networks, Inc.