[Al. 5E6_Ss1 Command Off Warning (Safety Sub-Function)] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 5E6_SS1 command off warning (safety sub-function)]

• The SS1 command was turned off.
[AL. 5E6.1_SS1 command off warning A (safety sub-function)]
Cause
1.
The SS1 command has been turned off
(enabled).
2.
An external 24 V DC power supply has not
been input to CN8.
3.
The servo amplifier has malfunctioned.
[AL. 5E6.9_SS1 command off warning B (safety sub-function)]
Page 199 [AL. 5E6.1_SS1 command off warning A (safety sub-function)]
Check/action method
Turn on (disable) the SS1 command.
Input the 24 V DC power supply.
Replace the servo amplifier.
1 SERVO AMPLIFIER TROUBLESHOOTING
1.3 Handling methods for alarms/warnings
1
Model
[G]
[WG]
199

Hide quick links:

Advertisement

Table of Contents
loading