[AL. 518_Synchronous control error (safety sub-function)]

• There is a problem with an internal part of the servo amplifier.
[AL. 518.2_Synchronous control error A2 (safety sub-function)]
Cause
1.
An internal part of the servo amplifier has
malfunctioned.
2.
There is a problem with the surrounding
environment.
[AL. 518.A_Synchronous control error B2 (safety sub-function)]
Page 138 [AL. 518.2_Synchronous control error A2 (safety sub-function)]
1 SERVO AMPLIFIER TROUBLESHOOTING
138
1.3 Handling methods for alarms/warnings
Check/action method
Replace the servo amplifier.
Check the power supply for noise. If there is noise, take countermeasures to
reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)