[AL. 514_Control process error (safety sub-function)]

• The process did not complete within the specified time.
[AL. 514.9_Control process error B (safety sub-function)]
Cause
1.
The servo parameter settings are incorrect.
2.
An internal part of the servo amplifier has
malfunctioned.
3.
There is a problem with the surrounding
environment.
[AL. 514.A_Control process error B2 (safety sub-function)]
Page 134 [AL. 514.9_Control process error B (safety sub-function)]
1 SERVO AMPLIFIER TROUBLESHOOTING
134
1.3 Handling methods for alarms/warnings
Check/action method
Return the servo parameter to the value it had before the alarm occurrence,
then check if the problem occurs again.
Replace the servo amplifier.
Check the power supply for noise. If there is noise, take countermeasures to
reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Model
[G]
[WG]