[Al. 5E2_Safety Communication Warning (Safety Sub-Function)] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 5E2_Safety communication warning (safety sub-function)]

• There is a problem with the safety communication.
[AL. 5E2.1_Safety communication no connection warning A (safety sub-function)]
Cause
1.
Connection with the controller has not been
established.
2.
The safety communication settings are
incorrect.
3.
The IP address was changed after connecting
to the controller.
[AL. 5E2.9_Safety communication no connection warning B (safety sub-function)]
Page 198 [AL. 5E2.1_Safety communication no connection warning A (safety sub-function)]
1 SERVO AMPLIFIER TROUBLESHOOTING
198
1.3 Handling methods for alarms/warnings
Check/action method
Page 200 The display shows "A" (unconnected to the controller)
Review the safety communication settings.
Refer to "Safety sub-function control by network" in the following manual.
MR-J5 User's Manual (Function)
If the IP address of the controller or the servo amplifier was changed after
connecting the controller, cycle the power.