[AL. 596_SS1 time-out warning (safety sub-function)]
• The deceleration monitor time has passed after the SS1 command was turned off.
[AL. 596.1_SS1 time-out warning A]
Cause
1.
The time set in [Pr. PSA03 SS1/SS2
deceleration monitor time] has passed after
the SS1 command was turned off (enabled).
2.
With [Pr. PSA02.2 Time/Deceleration monitor
setting] being set to "1" (perform deceleration
monitoring) and "off" (enabled) of the SS1
command being detected, the time set in [Pr.
PSA15 Safety sub-function - Speed detection
delay time] has passed since the servo motor
speed fell below the setting value of [Pr.
PSA04 Safety sub-function - Stop speed].
[AL. 596.9_SS1 time-out warning B]
Page 195 [AL. 596.1_SS1 time-out warning A]
Check/action method
Turn on (disable) the SS1 command.
1 SERVO AMPLIFIER TROUBLESHOOTING
1.3 Handling methods for alarms/warnings
1
Model
[G]
[WG]