Monitoring The Raid Array For The Ja2500 Junos Space Appliance - Juniper Junos Space JA2500 Hardware Manual

Hide thumbs Also See for Junos Space JA2500:
Table of Contents

Advertisement

JA2500 Junos Space Appliance Hardware Guide
Action
Sample Output
Meaning
Related
Documentation

Monitoring the RAID Array for the JA2500 Junos Space Appliance

Purpose
Action
78
Monitor the power supply modules. Do the following:
Log in to the appliance as the admin user.
1.
The Junos Space Settings Menu appears.
Type
6
, which is the
(Debug) run shell
2.
You are prompted to enter your password.
Type the password for the admin user and press Enter.
3.
You are taken to the shell.
Run the power status monitoring script:
4.
[root@host ~]# ./pwr_status_jnpr_v2.sh
NOTE:
The Junos Space installer automatically installs the i2c-tools
package and the power status monitoring script.
A sample output of the power monitoring script is as follows:
Juniper Product: JA2500
System Power Supply Status:
---------------------------
PS1 BTM MODULE: PRESENT
PS1 FAN STATUS: GOOD
PS1 OTP:
GOOD (<55C)
PS1 POWER:
GOOD
PS2 TOP MODULE: NOT DETECTED
The output of the
pwr_status_jnpr_v2.sh
power supply modules installed in the appliance.
Maintaining the Junos Space Appliance on page 87
Monitoring the Cooling Fans in a Junos Space Appliance on page 75
Monitoring the RAID Array for the JA2500 Junos Space Appliance on page 78
For optimal performance of the JA2500 appliance, monitor the status of the RAID volume
installed in the appliance.
Monitor the RAID controller for RAID failure events:
option.
script provides status information about the
Copyright © 2014, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents