Xantrex Powerpack 300 Owner's Manual page 55

Emergency power
Hide thumbs Also See for Powerpack 300:
Table of Contents

Advertisement

Electrical Specifications
AC Power Section
Output power
Continuous output power
Peak output power
AC output surge capacity
Output voltage
Output frequency
Output wave form
No load current draw
Input voltage range
Low battery alarm
Low battery shutdown
High battery voltage shutdown
Over temperature shutdown
Overload shutdown
AC output short circuit protection
Fuse (internal)
Operating temperature range
Storage temperature range
Internal Battery Charging Controller System
AC charger bulk charging current
Peak charging voltage (nominal)
Charge restart voltage (nominal)
Float charge after full charge is completed
(nominal)
AC charger input socket maximum current
42
240 W
300 W
480 W
120 ± 10 V AC RMS
60 Hz ± 1 Hz
modified sinewave
<0.20 A DC
10.5 to 15.5 V DC
11.0 V DC
10.5 V DC
Yes, automatic reset
Yes, automatic reset
Yes, automatic reset
Yes, automatic reset
25 A
0–40 ºC (32–104 ºF)
0–30 ºC (32–86 ºF)
500 mA
14.2 V
12.9 V
1 mA
2.5 A