Xantrex Powerpack 300 Owner's Manual page 50

Emergency power
Hide thumbs Also See for Powerpack 300:
Table of Contents

Advertisement

Table 5-1 Troubleshooting reference
Problem
AC appliance
will not
operate;
audible alarm
is sounding.
Run time is
less than
expected.
Possible Cause
Battery has discharged to
10.5 V.
XPower Powerpack has
overheated due to poor
ventilation or excessively
warm environmental
conditions.
XPower Powerpack
battery is not fully
charged.
AC appliance power
consumption is higher
than expected.
Environmental
temperature is less than
0°C (32°F) or more than
40°C (104°F)
Troubleshooting Reference
Solution
Turn
the AC Power
OFF
switch and recharge the XPower
Powerpack.
Turn the AC Power
switch
and allow the
OFF
XPower Powerpack to cool for
15 minutes or more. Clear
blocked opening or remove
objects covering the unit, then
restart the XPower Powerpack
and move it to a cooler
environment.
Recharge using the AC charger,
until Battery Status LED is
green.
Check AC appliance power or
wattage rating (or current draw
for 12 V DC appliances) and
compare with Table 3-1 on
page 14 and Table 3-2 on
page 17.
Operate within correct
temperature range.
/
ON
OFF
/
ON
OFF
37