Siemens ULTRAMAT 6 Manual page 126

Hide thumbs Also See for ULTRAMAT 6:
Table of Contents

Advertisement

Available languages

Available languages

7.5.4
Physical Block
Class
Sl
Index
Ind
Elem
Default
ot
abs
ex
ent
Value
rel
BLOCK
1
110
0
1
250
2
1
3
5
4
250
5
0
6
0
7
0x4002
8
0x0300
9
0
10
54
11
0x01b7
12
1
STD
111
1
0
STD
112
2
Analyser
STD
113
3
0
STD
114
4
0
STD
115
5
0x08
STD
116
6
1
0x08
2
0x88
3
0x08
STD
117
7
1
0x0000
2
0x0000
3
0x0000
4
0x0000
MAND
118
8
0.23
MAND
119
9
MAND
120
10
42
MAND
121
11
MAND
122
12
MAND
123
13
0x000000
00
OPT
124
14
MAND
125
15
0xBBBF0
000
OPT
126
16
OPT
127
17
CE,
NE21. Ex-
certificatio
n see
plate
OPT
128
18
2457
OPT
129
19
0
OPT
130
20
descriptor DESCRIPTOR
OPT
131
21
message
OPT
132
22
01.01.200
0
OPT
133
23
0
MAND
134
24
1
OPT
135
25
136
26
bis
142
32
ULTRAMAT 6 / OXYMAT 6 / CALOMAT 6 / ULTRAMAT 23 / OXYMAT 61
Schnittstelle PROFIBUS DP / PA Interface
A5E00054148-03
Physical Block PB
Object
BLOCK_OBJECT
Reserved
Block Object
Parent Class
Class
DD-Reference
DD-Revision
Profile
Profile Revision
Execution Time
NumberOfParameters
Address of VIEW 1
Number of View Lists
ST_REV
TAG_DESC
STRATEGY
ALERT_KEY
TARGET_MODE
MODE_BLK
Actual
Permitted
Normal
ALARM_SUM
Current_Alarm
Unacknowledged
Unreported
Disabled
/
SOFTWARE_REVISION
HARDWARE_REVISION
DEVICE_MAN_ID
DEVICE_ID
DEV_SER_NUM
DIAGNOSIS
DIAGNOSIS_EXTENSION
DIAGNOSIS_MASK
DIAGNOSIS_MASK_EXTENSION
DEVICE_CERTIFICATION
WRITE_LOCKING
FACTORY_RESET
DEVICE_MESSAGE
DEVICE_INSTAL_DATE
LOCAL_OP_ENA
IDENT_NUMBER_SELECTOR
HW_WRITE_PROTECTION
reserved by PNO
Parameter description
Block characteristic
250 = not used
Block-Typ (Function)
Parent class: 01 = Input
01 = Analog Input
reserved
reserved
PA-profil-number assigned by PNO for
PROFIBUS - PA = 64
Profile 3.0
f0r future use
number of parameters
Index of view 1
Number of views
Identification / device / statistic rev.-no. /
Function Block: counter which is incremented
at any change of configuration parameters
Unique tag in the system which can be used
by the user
Strategy
User can write value for alert handling
Target mode of block = Auto
Set block mode
Actual mode
Permitted modes: Auto, O/S, MAN
Set mode in normal operation
Alarm status
Current Alarm
Not acknowledged
Not reported
Disabled
Software Revision
Hardware Revision
Manufacturer
Device identification (unique)
Device serial number
Detailed device informations (bit coded)
Extended device information
Bits supported by DIAGNOSIS
Bits supported by DIAGNOSIS_EXTENSION
Device certification like EX, CE
Password
Reset to Default-Values
Message
Date of device installation
Local operation enable
Profile analyser spec. (0) Profile spec. (3)
Manufacterer spec. (1) DP-Ident Number
Hardware- Write Protection
Data Type
Num
Store
cy
ber
(acc. to
cli
profile)
c
ds32
1
C
unsigned8
1
unsigned8
1
unsigned8
1
unsigned8
1
unsigned32
1
unsigned16
1
unsigned16
1
unsigned16
1
unsigned8
1
unsigned16
1
unsigned16
1
unsigned8
1
unsigned16
1
N
visible_string
32
S
unsigned16
1
S
unsigned8
1
S
unsigned8
1
S
ds37
1
D
ds42
1
D
visible_string
16
D
visible_string
16
D
unsigned16
1
C
visible_string
16
C
visible_string
16
D
octet_string
4
D
octet_string
6
D
octet_string
4
C
octet_string
6
C
visible_string
32
C
unsigned16
1
N
unsigned16
1
S
visible_string
32
S
visible_string
32
S
octet_string
16
S
unsigned8
1
N
unsigned8
1
S
unsigned8
1
D
re
wri
ad
te
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
126