Siemens LMV51 Series Basic Documentation page 136

Burner control with integrated fuel / air ratio control and load control, load control including o2 trim control for forced draft burners
Hide thumbs Also See for LMV51 Series:
Table of Contents

Advertisement

Representation of parameters based on the AZL5... menu structure, «OEM» level, as supplied by Siemens
Menu level 1
Menu level 2
Menu level 3
OilSettings
136/301
Siemens Building Technologies
Basic Documentation LMV5...
HVAC Products
7 Display and operating unit AZL5...
Menu level 4
Menu level 5
Menu level 6
B / 1000
O2 Content Air
Type ofAir-
Change
O2 OffsetGas
LoadCtrlSus-
pend
FilterTimeLoad
OptgMode
O2 Control
O2 Monitor
Control Param
P low-fire
I low-fire
Tau low-fire
P nominal load
I nominal load
Tau nominal load
O2 CtrlThreshold
Type of Fuel
Fuel user def
V_LNmin
V_afNmin
V_atrNmin
Description
Adjustable constant for calculating the combustion efficiency
(gas)
Oxygen content of air
Impact of air density change on O2 value
O2 offset during change of load gas
Difference between delayed and current load
Filter time for delayed load
Parameter settings for firing on oil
Operating mode of O2 controller / limiter when firing on oil
Parameter settings for O2 trim control
Parameter settings for monitoring the function
P-part of O2 controller with low-fire
I-part of O2 controller with low-fire
Time constant Tau of O2 controller's controlled system with
low-fire
P-part of O2 controller with nominal load
I-part of O2 controller with nominal load
Time constant Tau of O2 controller's controlled system with
nominal load
Minimum load O2 control (oil)
Selection of type of oil
Air volume under standard conditions and lambda = 1
Flue gas volume wet under standard conditions and lambda =
1
Flue gas volume dry under standard conditions and lambda =
1
Value range
Access
Default pa-
LMV51 LMV52
rights
rameter
setting
1..20
Service
9
0..30 %
OEM
20.9 %
like theory
OEM
like theory
like P air
0...5 %
Serivice
0 %
0...25 %
Serivice
5 %
4...10
Serivice
5
Service
auto deact
Service
man deact
man deact
O2 Limiter
O2 Control
conAutoDeac
Service
Service
Service
3..500 %
Service
invalid
0..500 s
Service
invalid
1..27 s
OEM
invalid
3..500 %
Service
invalid
0..500 s
Service
invalid
1..27 s
OEM
invalid
0..100 %
Service
0 %
user def
Service
oil EL
oil EL
oil H
Service
0.00..40.00
Service
11.2
0.00..40.00
Service
12.02
0.00..40.00
Service
10.53
CC1P7550en
13.08.2004
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents