ABB IRC5 Compact Product Manual page 60

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

2 Installation and commissioning
2.6.1.3 Connectors on the computer unit
Continued
LAN 2 can only be used as private network to the IRC5 controller.
Isolated LAN 3 or LAN 3 as part of the private network (only for RobotWare 6.01 and later)
The default configuration is that LAN 3 is configured as an isolated network. This
allows LAN 3 to be connected to an external network, including other robot
controllers. The isolated LAN 3 network has the same address limitations as the
WAN network.
Service
xx1500000393
An alternative configuration is that LAN 3 is part of the private network. The ports
Service, LAN 1, LAN 2, and LAN 3 then belong to the same network and act just
as different ports on the same switch. This is configured by changing the system
parameter Interface, in topic Communication and type Static VLAN, from "LAN 3"
to "LAN". See Technical reference manual - System parameters.
Service
xx1500000394
For more information and examples of connecting to different networks, see
Application manual - EtherNet/IP Scanner/Adapter or Application
manual - PROFINET Controller/Device.
USB ports
The USB ports are intended for connecting USB memory devices.
It is recommended to use the USB ports USB
for connecting USB memory devices.
The USB ports on the X11 connector are intended for internal use.
60
Robot Controller
Isolated
Public
Private
LAN 3
LAN 2
LAN 3
LAN 1
WAN
Robot Controller
Public
Private
LAN 1
LAN 2
LAN 3
WAN
Note
Note
© Copyright 2009-2017 ABB. All rights reserved.
1
2
and USB
on the X10 connector
Product manual - IRC5 Compact
3HAC047138-001 Revision: G

Hide quick links:

Advertisement

Table of Contents
loading