Removal
Use this procedure to remove the Ethernet switch.
1
2
3
4
5
6
7
8
Product manual - IRC5 Compact
3HAC047138-001 Revision: G
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
DANGER - Make sure that the main power has been
switched off! on page
33.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the section
WARNING - The unit is sensitive to ESD! on page 34
On the cabinet front, disconnect the connectors
from the Ethernet switch contacts.
If you have a Remote Service box, disconnect the
connectors from this as well.
Remove the cover of the cabinet.
Disconnect all connectors from the safety board,
Ethernet switch, and Remote Service box.
Remove the two attachment screws, and push the
safety board unit backwards to release the latches.
Remove the attachment screws, and lift off the
safety board.
Remove the Ethernet switch.
© Copyright 2009-2017 ABB. All rights reserved.
4.18 Replacement of Ethernet switch
Information
A
xx1400002787
A Remote Service contacts
B Ethernet switch contacts
See
Opening the IRC5 Compact
controller on page
xx1400001462
xx1500000231
Continues on next page
4 Repair
Continued
B
89.