Refitting the Safety module
1
2
3
4
5
6
Product manual - IRC5 Compact
3HAC047138-001 Revision: G
4.7 Replacement of Safety module DSQC1015 for SafeMove
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety inform-
ation in section
DANGER - Make sure that
the main power has been switched off! on
page
33.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit please observe the safety in-
formation in section
WARNING - The unit
is sensitive to ESD! on page 34
Fit the Safety module in position by push-
ing it into the socket on the motherboard.
Refit the attachment screw on top of the
Safety module bracket.
Refit the fan connector and close the com-
puter unit.
CAUTION
Be careful with the fan cable when closing
the cover. The fan cable must not be
squeezed.
Refit the computer unit.
© Copyright 2009-2017 ABB. All rights reserved.
Note/Illustration
xx1500001761
A Attachment screw
B Safety module
CAUTION
Always grip the board around the edges to
avoid damage to the board or its compon-
ents.
xx1300000684
A Attachment screws (4 pcs.)
B Cover
See
Replacement of computer unit on
page
138.