2 Installation and commissioning
2.11.1 Installation of external operator's panel
Continued
Procedure
The procedure below details how to install the external control panel.
1
2
3
4
5
6
7
Continues on next page
100
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety informa-
tion in section
DANGER - Make sure that
the main power has been switched off! on
page
33.
Remove the cover of the cabinet.
Remove the two attachment screws for the
safety board unit and gently pull it out a
little bit.
Remove the contactor unit (contactors at-
tached with plate) attachment screws and
move the unit leftwards a little bit.
Disconnect signal cabling from the safety
board.
Connectors:
A21.X6
A21.X9
Detach the Emergency stop button, Motor
on button and Mode switch together with
their cabling on the controller. Mount these
buttons and switch on the external operat-
or's panel and strap the cabling to the exist-
ing cable strapping behind the front panel.
Connect the round connector from the ex-
ternal operator's panel harness to XS4 on
the controller.
© Copyright 2009-2017 ABB. All rights reserved.
Info/illustration
See
Opening the IRC5 Compact controller
on page
89.
X9
X6
xx1500000114
Product manual - IRC5 Compact
3HAC047138-001 Revision: G