Strength Of The Ball Screw Spline - Epson LS10-B Series User Manual

Hide thumbs Also See for LS10-B Series:
Table of Contents

Advertisement

1.2.1 Strength of the Ball Screw Spline

If a load exceeding the allowable value is applied to the ball screw spline, it may not work
properly due to deformation or breakage of the shaft. If the ball screw spline is applied the
load exceeding the allowable value, it is necessary to replace the ball screw spline unit.
The allowable loads differ depending on distance where the load is applied to.
calculating the allowable load, see the calculation formula below.
[Allowable bending moment]
[Moment]
Example:
LS10-B Rev.6
M=50,000 N·mm
M=F·L
100·200
20,000 N·mm
If 100 N (10.2kgf) load is applied
at 200 mm from
the end of the spline nut
Setup & Operation 1. Safety
End of the
L
spline nut
F
For