【 RS-485 】
PTZ Protocol: Select PTZ protocol, choose from the following protocols: Transparent, Pelco_D,
Pelco_P, Everfocus or Samsung. (Note: All cameras on the RS-485 bus must use the same
protocol)
Type: Select a type.
485 ID: This is the ID used by the EKB500 to send commands to the mobile DVR. On an RS-485
connection, every device (PTZ, mobile DVR and controller) must be assigned an unique ID
number between 0 and 127.
Baud Rate: This field is to set the speed at which is used to transmit instruction or
information through the RS-485 port on the mobile DVR. There are eight different speeds:
1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings for
this option: 8 or 7.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop
bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose
between None, Odd, or Even parity levels.
【GPS】: If you are using EverFocus GPS Receiver (please refer to 1.3 Optional Accessories), please
configure the settings below for GPS function to work.
Baud Rate: This field is to set the speed at which is used to transmit instruction or information
through the RS-485 port on the mobile DVR. There are eight different speeds: 1200 BPS, 2400 BPS,
4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings for this
option: 8 or 7.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop bits,
1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose
between None, Odd, or Even parity levels.
Control: One remote control can be used to operate four mobile DVRs. The mobile DVR to be
addressed is selected by pressing the key corresponding to its ID number on the IR Remote
control. Please refer to Appendix D: IR Remote Control.
IR Controller ID: Set up an ID for the mobile DVR and allow the IR remote control to control