1.9.2 RETURN TO SERVICE INFORMATION

These return to service procedures are intended to verify the serviceability of the
appliance only. These tests alone do not verify or otherwise validate the airworthiness
of the installation.
pitot/static
NOTE: A
be completed if the pitot/static lines are broken.
1.9.2.1 ORIGINAL G5 IS REINSTALLED
No software or calibration is required if the original G5 is reinstalled in its original
mounting location.
1.9.2.2 NEW G5 IS INSTALLED
Any time a new G5 is installed, or an existing G5 is moved to a different mounting
location, the pitch/roll offset calibration procedure (Section 1.7.4.2.2) must be
performed. The correct G5 software version will automatically be loaded into the G5
from a connected GDU (if applicable). If a GDU is not connected, the unit software
will need to be loaded via the front-facing microSD™ card slot. All unit configuration
options will need to be selected as the G5 does not support a config module.
190-02072-00 Rev. B
check as outlined in 91.411 and Part 43 Appendix E must
Garmin G5 User's Manual
Installation Manual
85