Siemens 7XV5662-0AB01 Directions For Use Manual page 64

Communication converter s0-bus with optical asynchronous input interface
Table of Contents

Advertisement

Available languages

Available languages

English
aciomcatab1
03056789
aciomcatab2
091112345
isdn 0
vmoddi/1.msni
04012345
vmoddi/2.msni
04067890
save
show
reset
Table 15: Parameter assignment CC–S
Command
defa 1
aciomco 2
aciomcatab1
04067890
aciomcatab2
03012345
isdn 0
vmoddi/1.msni
091112345
vmoddi/2.msni
091167890
save
show
reset
Table 16: Parameter assignment CC–S
64
03056789 is the dialled number for FO1/LWL1
091112345 is the dialled number for FO2/LWL2
sets the ISDN–Protocol to DSS1 (Dialling Line)
If the an incoming call had dialled 04012345 the data are
routed through FO1/LWL1
If the an incoming call had dialled 04067890 the data are
routed through FO2/LWL2
save the assigned parameters into a resident memory
show the actual parameters of the CC–S
restarts the CC–S
0
#2 (Hamburg)
0
Description
resets all parameter to the state of delivery
only one B–Channel starts dialling after Reset/Power On or an
interruption of the communication. The dialled number is
03012345 (assigned at aciomcatab2)
04067890 is the dialled number for FO1/LWL1
03012345 is the dialled number for FO2/LWL2
sets the ISDN–Protocol to DSS1 (Dialling Line)
If the an incoming call had dialled 091112345 the data are
routed through FO1/LWL1
If the an incoming call had dialled 091167890 the data are
routed through FO2/LWL2
save the assigned parameters into a resident memory
show the actual parameters of the CC–S
restarts the CC–S
0
#3 (Nuremberg)
0
with the new assigned parameters
with the new assigned parameters
(see figure 37)
0
(see figure 37)
0
C53000-B1174-C166-1