Gun Placement

Installation

1. Install vertical gun mount onto gun bar.
NOTE: Make sure all hoses, cables, and wires are
properly routed through brackets.

Trigger Sensor Adjustment

1. Start striper engine. Pull trigger. Spray icon should
appear simultaneously with start of fluid spray.
20
No fluid spray
2. Turn screw in handle clockwise if spray icon
appears before fluid spray starts.
ti27801a
No spray icon
3. Turn screw in handle counterclockwise if fluid spray
starts before spray icon appears.
4. Continue adjusting screw in trigger until timing of
spray icon and fluid spray are synchronized.
ti27883a
ti27802a
ti27803a